HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999)

Troubleshooting
Event Code Descriptions
180
Troubleshooting
Event
Number
(DEC/hex)
Event Name Event
Logged
Predictive
Maintenance
Implication
Suspected
Components
Description
213/0xd5
Secondary
Controller
Failed, Entered
Isolation Mode
Y
Ignore if
corrected by
power cycle
Controller
Backplane
A controller was discovered to
be bad during power on.
Specifically, the secondary
controller appears to have
failed due to an event which
caused isolation mode to be
entered. In isolation mode
controller X becomes the
primary controller and
controller Y is offline.
This may be recovered by
power cycle.
214/0xd6
Secondary
Controller
Failed, Entered
Separation
Mode
Y
Ignore if
corrected by
reset or power
cycle
Controller
Backplane
A controller was discovered to
be bad during power on.
Specifically, the secondary
controller appears to have
failed due to an event which
caused separation mode to be
entered. In separation mode,
the NVRAM contents is not
mirrored between controllers.
This may be recovered by
reset or power cycle.