HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999)
Troubleshooting
Event Code Descriptions
179
Troubleshooting
Event
Number
(DEC/hex)
Event Name Event
Logged
Predictive
Maintenance
Implication
Suspected
Components
Description
210/0xd2
Correctable
ECC Error
During
Initialization
Y More than 1
in 6 months if
no operator
activity
SIMM
Controller
The controller experienced an
unrecoverable error during
power on. This is expected in
any of the following
situations:
- The batteries have been fully
discharged.
- The batteries were
disconnected from the
memory
- New SIMM memory was
added
All other situations, this event
represents a true memory
error.
211/0xd3
Controller
Failed Local
Address Decode
Test
Y
Ignore if
corrected by
reset or power
cycle.
SIMM
Controller
A controller was discovered to
be bad during power on.
Specifically, the secondary
controller appears to have
failed the request to perform a
local memory decode test or
was unable to establish
communication with the other
controller. This may be
recovered by power cycle or
reset.
212/0xd4
Controller
Failed Remote
Address Decode
Test
Y
Ignore if
corrected by
reset or power
cycle.
SIMM
Controller
Backplane
A controller was discovered to
be bad during power on.
Specifically, the secondary
controller appears to have
failed the request to perform a
remote memory decode test or
was unable to establish
communication with the other
controller. This may be
recovered by power cycle or
reset.