HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999)
Troubleshooting
Event Code Descriptions
178
Troubleshooting
Event
Number
(DEC/hex)
Event Name Event
Logged
Predictive
Maintenance
Implication
Suspected
Components
Description
208/0xd0
Internal SCSI
Bus State
Event
Y
Single
Occurrence
Controller
Disk Drive
Internal SCSI
Bus
A disk drive responded
incorrectly. The result was an
internal SCSI bus reset, and a
hot-plug recovery sequence to
regenerate the bus state. The
control panel display may
indicate “verifying drives” as
a result of the internal bus
reset.
209/0xd1
Uncorrectable
ECC Error
During
Initialization
Y More than 1
in 6 months if
no operator
activity
SIMM
Controller
The controller experienced an
unrecoverable error during
power on. This is expected in
any of the following
situations:
- The batteries have been fully
discharged.
- The batteries were
disconnected from the
memory
- New SIMM memory was
added
All other situations, this event
represents a true memory
error.