HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999)
Troubleshooting
Event Code Descriptions
177
Troubleshooting
Event
Number
(DEC/hex)
Event Name Event
Logged
Predictive
Maintenance
Implication
Suspected
Components
Description
203/0xcb
Replace
Batteries
Y
Single
Occurrence
Batteries
Controller
The batteries have failed a
discharge test or have dropped
below an acceptable voltage
level. Both batteries should be
replaced.
204/0xcc
Cache Shrink
Attempted After
Shutdown
Warning
Y
Ignore - see
errors during
shutdown
None The amount of cache on the
controller has shrunk due to
SIMM failure or removal.
This happened with valid
writes still in cache, and all
the writes no longer fit in the
reduced amount of cache.
205/0xcd
Controller
Failed
Y Ignore if
corrected by
reset or
power cycle
Controller During power on, a bad
controller was detected. This
may result if the controller has
difficulty establishing
communication. Ignore if
recovered by power cycle or
reset.
206/0xce
SIMM Failed
Y
Single
Occurrence
SIMM
Controller
A SIMM was discovered to be
bad during power on.
207/0xcf
Extended
Drive
Installation
Event
Y
Ignore unless
no operator
activity
Disk Drive
Controller
Internal SCSI
Bus
An internal SCSI channel is
being held reset longer than
expected. Typically caused by
a partially-installed drive
module, a failing drive
module, a failing controller, or
a bent pin on a connector.