HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999)
Troubleshooting
Event Code Descriptions
176
Troubleshooting
Event
Number
(DEC/hex)
Event Name Event
Logged
Predictive
Maintenance
Implication
Suspected
Components
Description
198/0xc6
Fan Failed
Y
Single
Occurrence
Fan
Controller
Backplane
A fan has failed and should be
replaced.
199/0xc7
Power Supply
Failed
Y
Single
Occurrence
Power Supply
Controller
Backplane
A power supply has failed and
should be replaced.
200/0xc8
Power Down
Due To Fan
Failure
Y
Single
Occurrence
Fans
Controller
Backplane
The controller has detected
that not enough fans are
functioning to cool the disk
array properly. As a result, the
controller is shutting off the
power supply to avoid
overheating.
Note: The NVRAM is not
posted to disk, so it is critical
to repair the system quickly.
201/0xc9
Fan Missing At
Initialization
Y
Ignore - See
accompanying
errors.
None During startup, the controller
detected that a fan had been
removed from the enclosure.
The total length of time a fan
has been missing will be
checked periodically and
when it exceeds
approximately 10 minutes, the
controller will shut off the
power supply.
202/0xca
Power Down
Due To Missing
Fan
Y
Single
Occurrence
Fan
Controller
Backplane
The controller is shutting off
the power supply because a
fan has been missing from the
enclosure for too long
(approximately 10 minutes).