HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999)

Troubleshooting
Event Code Descriptions
172
Troubleshooting
Event
Number
(DEC/hex)
Event Name Event
Logged
Predictive
Maintenance
Implication
Suspected
Components
Description
183/0xb7
Cancel Rebuild
Started
Y
Ignore -
Operator or
Host activity
None A rebuild has been canceled
either automatically or by
command. The disk array
automatically cancels a
rebuild if it needs to restart
rebuild due to a disk addition,
a LUN deletion, or a LUN
format.
184/0xb8
Rebuild IO
Priority
Changed
Y
Ignore - Host
activity
None The host has changed the
rebuild priority.
185/0xb9
Non-Member
Drive Removed
Y
Ignore -
Operator
activity
None The controller detected that a
disk drive was removed. This
event occurs for drives that are
not disk set members when
they are removed. The device
number field is not used.
186/0xba
Drive Missing
At Power On
Y
Ignore unless
no Operator
activity
Disk Drive
Controller
Internal SCSI
Bus
Indicates that a disk drive was
discovered to be missing
during a power on or reset.
This event occurs for disk set
members only.
The disk drive ID number
assigned to the missing drive
appears in the component
identifier field of this log
entry. A disk drive ID number
consisting of the controller
serial number followed by a 0
indicates that the disk drive ID
number has not yet been
assigned.