HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999)

Troubleshooting
Event Code Descriptions
171
Troubleshooting
Event
Number
(DEC/hex)
Event Name Event
Logged
Predictive
Maintenance
Implication
Suspected
Components
Description
178/0xb2
Data
Unavailable
Y
Ignore - See
accompanying
errors
None The data unavailable condition
was triggered. This is caused
by multiple failed, downed, or
missing disk drives. The
condition persists as a warning
until fewer than 2 drives are
down, failed, or missing.
If this condition occurred as a
result of removing disk drives,
reinstall them to correct the
problem.
This event also occurs if data
and redundancy have been lost
for any part of the disk set.
The disk array must be
reformatted in this case.
179/0xb3
Insufficient
Optimal Space
For Rebuild
Y
Ignore - See
accompanying
errors
None There is insufficient disk
space for rebuild to execute.
This event is most likely to
occur when using disk drives
of different capacities.
To create the necessary disk
capacity, add another disk
(equal in capacity to the
largest disk in the array) or
delete a LUN.
180/0xb4
Rebuild
Restarted
Y
Ignore None A rebuild has been
automatically restarted due to
a disk failure or a disk
removal.