HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999)
Troubleshooting
Event Code Descriptions
162
Troubleshooting
Event
Number
(DEC/hex)
Event Name Event
Logged
Predictive
Maintenance
Implication
Suspected
Components
Description
144/0x90
Disk Drive
Installed
Y
Ignore -
Operator
Activity
None The controller has detected the
installation of a new disk
drive. This event occurs
regardless of the disposition of
the drive toward the disk set.
The disk drive ID number
assigned to the drive installed
appears in the component
identifier field of this log
entry. A disk drive ID number
consisting of the controller
serial number followed by a 0
indicates that the disk drive ID
number has not yet been
assigned.
145/0x91
Disk Drive
Added To Disk
Set
Y
Ignore -
Operator
activity
None The controller has included a
new disk drive in the disk set.
This event occurs only when a
disk drive that was not
previously a member of the
disk set becomes a member. It
does NOT occur when a
down, failed, or missing disk
is returned to ready status.
The disk drive ID number
assigned to the drive added
appears in the component
identifier field of this log
entry.