HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999)

Troubleshooting
Event Code Descriptions
159
Troubleshooting
Event
Number
(DEC/hex)
Event Name Event
Logged
Predictive
Maintenance
Implication
Suspected
Components
Description
135/0x87
No Disk Drives
Found During
Initialization
Y
Ignore -
Operator
activity
None During startup no disk drives
were present. A new disk set
was created with no members.
136/0x88
Insufficient
Space During
Rebuild
Y
Ignore - See
accompanying
errors.
None There is insufficient disk
space for migrating data
during a rebuild. This is a
controller error, although the
disk array may still support
some I/Os without adding
disks.
137/0x89
Rebuild Started
Y
Ignore - See
accompanying
errors.
None A rebuild has been started
either automatically or by
command.
138/0x8a
Rebuild
Complete
Y
Ignore None A rebuild has completed
successfully.
139/0x8b
Insufficient
Space To Start
Rebuild
Y
Ignore - See
accompanying
errors
None A rebuild was not started due
to insufficient disk space. This
event is most likely to occur
when Active Hot Spare is not
enabled.
To create the necessary disk
space, add a disk or delete a
LUN.
140/0x8c
Rebuild Failed
Y
Ignore - See
accompanying
errors
None Rebuild has failed to complete
due to multiple disk failures or
a controller failure. Previous
messages in the log should
indicate whether or not there
have been multiple disk
failures.