HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999)

Troubleshooting
Event Code Descriptions
157
Troubleshooting
Event
Number
(DEC/hex)
Event Name Event
Logged
Predictive
Maintenance
Implication
Suspected
Components
Description
102/0x66
Disk drive
reported a
SMART event
Y Signals
internal drive
errors
threshold
exceeded,
probable disk
failure in
future
Disk Drive
The disk drive reported a
SMART event. The event is
logged and the common sense
data is updated for all regular
read/write and passthru
commands. The precedence
for SMART event data in the
common area is low, so that
other errors that occur during
the same I/O are reported back
to the host. A SMART event
does not affect the I/O except
that it does count as one try of
the I/O.
128/0x80
Access Time
Count Error
Y
Ignore None The frequency distribution
table used to locate recently
modified blocks was found to
be inconsistent. This problem
is self correcting.
129/0x81
Disk Drive
Placed In Failed
State
Y
Single
Occurrence
Disk Drive
Controller
Internal SCSI
Bus
The controller failed a disk
drive due to its accumulated
error history. Replace the
failed disk drive.
130/0x82
NVRAM Image
Out Of Date
Y
Ignore -
Operator
activity
None This event would occur if the
disk drives were moved from
one disk array to another, and
then reinstalled in the original
array. The result is that the
controller will detect a
different stamp on the disks.