HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999)

Troubleshooting
Event Code Descriptions
149
Troubleshooting
Event
Number
(DEC/hex)
Event Name Event
Logged
Predictive
Maintenance
Implication
Suspected
Components
Description
65/0x41
Optimal Space
Error In RAID 1
Y
Ignore None The controller detected that
space allocated for an
"optimal only" migrating write
(i.e. rebuild policy) was no
longer optimal after the write
had completed. This event is
logged for debugging
purposes only and requires no
action.
66/0x42
No Shutdown
Image Posted
N
NA None The controller could not
shutdown the disk array
because all the disk drives
were missing. Reinstall the
missing disks to shutdown the
array.
67/0x43
Bad Disk Drive
State During
Add Physical
Drive
N
NA None An Add Physical Drive
command failed with the disk
returning a status of
Initialization Failed. The drive
is failing initialization, so
information on the nature of
the failure should appear in
the event log in a separate
entry.
68/0x44
Internal SCSI
Underrun
N
NA None A disk drive sent/received less
data than expected.
69/0x45
Internal SCSI
Overrun
N
NA None A disk drive sent/received
more data than expected.
70/0x46
Internal SCSI
Timeout
N More than 2
occurrences
per hot plug
event
Disk Drive
Controller
Internal SCSI
bus
A disk drive didn’t respond
within a specified time limit.
The disk drive may be failing,
or it may be busy performing
data retries.