HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999)
Troubleshooting
Event Code Descriptions
144
Troubleshooting
Event
Number
(DEC/hex)
Event Name Event
Logged
Predictive
Maintenance
Implication
Suspected
Components
Description
42/0x2a
Pass Through
Reset Failed
Y
Ignore None A command to the disk drive
failed. Drive status should be
returned and can be examined
to determine the condition of
the disk drive.
43/0x2b
Recovered With
RAID 1
Redundancy
Y
Ignore - See
Accompanying
Errors
None Redundancy was used by the
controller in the successful
completion of a read or write.
44/0x2c
Unavailable
Data Detected
By RAID 1
Y
Ignore - See
accompanying
errors
None The controller detected that
the disk drives necessary for a
read or write were not
available for access before the
access was attempted. This
can apply to an initial attempt
to read or write, or to a retry.
45/0x2d
Shutdown
Failed
N
NA None The controller could not
shutdown the disk array
because all the disk drives
were missing. Reinstall the
missing disks to shutdown the
array.
47/0x2f
Disk Drive
Removed
During Add
Physical Drive
N
NA None A disk drive was removed
from the disk array while an
Add Physical Drive command
was in progress against the
drive.