HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999)
Troubleshooting
Event Code Descriptions
139
Troubleshooting
Event
Number
(DEC/hex)
Event Name Event
Logged
Predictive
Maintenance
Implication
Suspected
Components
Description
18/0x12
Not Enough
Space
Y
Ignore None A write command had to
move data in order to find
enough space to complete.
Errors were encountered
during this process which
prevented the controller from
providing enough space for
the write.
This would typically result
from multiple failing or
missing drives. If disk drives
have been removed, reinstall
them in the array.
19/0x13
Command
Illegal In
Current State
N
NA None The requested operation is not
allowed due to the current
state of the disk array. Certain
operations require the disk
array to be in a specific state
for execution. For example,
the disk array must be
shutdown to perform a
download.
20/0x14
Becoming
Ready
N
NA None The disk array has not finished
its initialization.
21/0x15
Recovered With
Low Level
Retries
Y
Ignore
Disk Drive
Controller
Internal SCSI
Bus
After failing the initial I/O,
data was recovered using
retries. It was necessary to
use redundancy to recover the
data.