HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999)
Troubleshooting
Event Code Descriptions
138
Troubleshooting
Event
Number
(DEC/hex)
Event Name Event
Logged
Predictive
Maintenance
Implication
Suspected
Components
Description
12/0x0c
Hardware Error
Unit Attention
N
NA None Power on or self-test failure.
Check system state and
warning states for more
information.
13/0x0d
Commands
Cleared Unit
Attention
N
NA None Commands cleared by another
initiator. See the SCSI
Command Specification for
more information.
14/0x0e
Mode
Parameters
Changed Unit
Attention
N
NA None Mode parameters changed by
other initiator. See the SCSI
Command Specification for
more information.
15/0x0f
Unconfigured
LUN
N
NA None A command tried to address a
LUN that hasn’t been created.
16/0x10
Invalid Target
LUN
N
NA None A command tried to perform
an illegal operation on the
specified LUN. For example,
trying to create a LUN that
already exists.
17/0x11
Invalid Source
LUN
N
NA None A command tried to renumber
a LUN that doesn’t exist.