HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999)
Troubleshooting
Event Code Descriptions
137
Troubleshooting
Event
Number
(DEC/hex)
Event Name Event
Logged
Predictive
Maintenance
Implication
Suspected
Components
Description
6/0x06
Invalid Opcode
N
NA None A SCSI invalid opcode error
occurred. See the SCSI
Command Specification for
more information.
NOTE. In certain disk array
states, this event may occur
even if the opcode is valid.
These are typically states that
indicate a larger problem with
the disk array.
7/0x07
Invalid Bit In
CDB
N
NA None Invalid bit in CDB. See the
SCSI Command Specification
for more information.
8/0x08
Logical Block
Address Out Of
Range
N
NA None The specified logical block
address was out of range. See
the SCSI Command
Specification for more
information.
9/0x09
Not Ready
N
NA None Not Ready, Init command
required.
10/0x0a
Invalid Identify
Received
N
NA None Invalid Identify Received. See
the SCSI Command
Specification for more
information.
11/0x0b
Power On Unit
Attention
N
NA None Power on unit attention. See
the SCSI Command
Specification for more
information.