HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999)
Troubleshooting
Control Panel Error Messages
126
Troubleshooting
Table 11. Control Panel Error Messages (Disk States)
Error Message Explanation Action
Disk States:
Current Log Disk
Log information is being logged on the
specified log disk.
None. Information only.
Disk States:
Downed
The disk module is in a Not Included state. The user requested the array to enter this state.
Use the Include Disk command if you want to
include the disk module.
Disk States:
Failed
The disk module is in a failed state. Replace the disk module.
Disk States:
Failed Setup
The disk module failed during initialization. Replace the disk module.
Disk States:
Log Disk Failed
The log disk has failed. Return the log disk to the factory for a
replacement.
Disk States:
Log Disk Full
The log disk is full and ready to be evaluated. Return the log disk to the factory for an
evaluation of the log.
Disk States:
Not Included
The disk module is not part of a logical drive.
Auto Include is OFF.
You must manually include the disk module to
make it become part of the logical drive set.
Disk States:
Previously Used
The disk module has been used in a different
array.
None. Information only.
CAUTION: The disk module may be used in
the present array, but the original data will
be lost when Include Disk is executed.
Disk States:
Ready
The disk module is in a ready state. None. Information only.
Disk States:
Unknown
The disk module is in an unknown or
unexpected state.
Call the support line and remove the disk
module.
Disk States:
Unsupported
This type of disk module is unsupported and
has not been tested.
CAUTION: Replace the disk module with one
that is supported. Inclusion of this disk module
may cause unpredictable results or loss of data.
Disk States:
Unused Log Disk
More than one log disk is installed. This log
disk will not be used.
None. Information only.