HP SureStore E Disk Array 12H User's and Service Manual (C5445-90901, September 1999)

Troubleshooting
Power On Sequence Test
122
Troubleshooting
Sequence
Code
Description of Power On Sequence Test Performed
44 remote SIMM 2, 2nd half test (32 MB SIMMs only)
46 SIMM 0, 1st half test
48 SIMM 0, 2nd half test (32 MB SIMMs only)
50 remote SIMM 0, 1st half test
52 remote SIMM 0, 2nd half test (32 MB SIMMs only)
54 remote SIMM 0, 2nd half test retry (32 MB SIMMs only)
60 initialize remote board NVRAM
62 test local NVRAM checksum
64 test remote NVRAM checksum, part 1
66 test remote NVRAM checksum, part 2
68 NVRAM consistency check
70 sync communication areas
72 determine if download is required
74 test for nocode on primary or secondary
76 no download required; check for personality mismatch
78 chip initialization
80 initialize NVRAM for clients
82 jump to OS
90 drive spinup and configuration
95 map and cache upload
99 final initialization