HP SureStore E Disk Array FC60 Service Manual (A5635A)

76 Recommended Disk Array Configurations
Two Disk Enclosure Configurations
High Availability/ High Performance
Hardware Configuration
Two disk array controllers connected directly to host Fibre Channel adapters
Two disk enclosures with ten 73 GByte disk modules (20 disks total)
Disk enclosures configured for split-bus mode (two SCSI channels per enclosure)
Volume Group Configuration
Ten RAID 1 volume groups, each comprising two disks (1+1)
Each disk in a volume group is in a separate enclosure
High Availability
Handles a single disk failure, BCC failure, single channel failure, or a single
controller failure.
Expansion requires powering down the disk array, removing terminators and/or
cables from the enclosures, and cabling additional disk enclosures.
Disk Capacity
Maximum capacity 1460 GBytes
Usable capacity 730 GBytes