Controller Enclosure Troubleshooting 261
Troubleshooting
Note
The BBU has a two-year life expectancy. The BBU is a sealed unit and must be
replaced as an entire assembly. The batteries inside the BBU are not separately
replaceable.
Types of Power System Problems
Some electrical problems are difficult to trace, especially if they involve complex site
wiring in a large facility. However, you can use the controller enclosure’s LEDs and a few
simple procedures in this chapter to determine if the power problem is in the controller
enclosure, the rack, or the building.
Hardware-Related Problems
Problems in the hardware components in the controller enclosure’s power system include:
Loose or damaged power connectors
Disconnected or damaged power cables
Weak or failed batteries
Failed power supplies
Failure of other power-related components of the controller enclosure
Power failure of the power unit (internal AC distribution unit or UPS)
Power failure of the external AC source (building circuit breakers, wiring, or UPS)