HP SureStore E Disk Array FC60 Service Manual (A5635A)

Controller Enclosure Troubleshooting 235
Troubleshooting
0xE6 Software load failure
Firmware file is bad /
Download Firmware
with a good file.
0xE7 Kernel missing, or kernel CRC
mismatch
0xE8 Application Firmware missing, or
Application CRC mismatch
0xEA Swapped controller
Controller is in wrong
slot.
0xF1 Processor set-up HW Init. status
Controller module /
reseat or replace
0xF2 CDC chip set-up
0xF3 RAID Parity Assist chip set-up
0xF4 Memory Test
0xF5 Load Boot Firmware
0xF7 Clear Boot memory
0xF8 Enable Protected mode
0xF9 Memory test failure
0xFA Exception error
0xFB Start mode determination
0xFC Invoke Boot Firmware
0xFF Hardware reset
Hardware reset is in
progress or there is a
bad controller
module.
Table 30
Controller Status LEDs codes (cont’d)
Code Description Comments Cause / Solution