HP SureStore E Disk Array FC60 Service Manual (A5635A)
Controller Enclosure Troubleshooting 233
Troubleshooting
0x91 Intermodule error call to flash
function passed bad flash type
Firmware file is bad / Download Firmware
with a good file.
Attempt to download Firmware
again. If the problem persists, replace the
controller module.
0x92 Invalid address in flash device
Firmware file is bad / Download Firmware
with a good file.
Attempt to download Firmware
again. If the problem persists, replace the
controller module.
0x93 Length too long for flash device
0x95 Unable to fully erase boot flash
segments
Controller module /
reseat or replace
0x96 Unable to fully erase file flash
segments
0x97 Unable to program boot flash
after 3 cycles of erase and write
0x98 Unable to program application file
flash after 3 cycles of erase and
write
0xA1 Start Boot Firmware Boot Funct. Status
0xA2 Initialize core hardware
0xA3 Determine hardware configuration
0xA4 Determine CDC memory size
0xA5 Determine RAID Parity Assist
memory size
0xA6 Initialize BIOS timer
0xA7 Initialize serial interface
0xA8 General software initialization
0xA9 Display Boot banner
0xAA Test Boot Menu invocation
0xAA
(steady)
PCI fatal fault
0xAB Test Boot Menu memory Boot Funct. Status
Memory problem /
reseat or replace
Table 30
Controller Status LEDs codes (cont’d)
Code Description Comments Cause / Solution