HP SureStore E Disk Array FC60 Service Manual (A5635A)
230 Controller Enclosure Troubleshooting
0x36
0x00
Processor DRAM diagnostics
running
HW Diag. status
Controller module /
reseat or replace
0x37
0x00
RPA DRAM diagnostics running
0x38
0x00
Processor Level 2 Cache
diagnostics running
0x44
0x01
CDC diagnostics running
0x44
0x02
SIO diagnostics running
0x44
0x03
RPA diagnostics running
0x44
0x12
SIO Interrupt diagnostics running
0x54
0x00
ICON
diagnostics running
0x55
0x00
FReD diagnostics running
0x61 Download file is lacking header
record
Firmware file is bad /
Download Firmware
with a good file.
0x64 Download file header fails
checksum test
0x65 Download file header contains
unexpected download type
0x65
0x00
Host SCSI Channel (53C825)
diagnostics running
Controller module /
reseat or replace
0x65
0x10
Host SCSI Channel (53C875)
diagnostics running
0x65
0x20
Host Fibre Channel Interface
diagnostics running
0x67 CRC failure on downloaded data
Table 30
Controller Status LEDs codes (cont’d)
Code Description Comments Cause / Solution