HP SureStore E Disk Array FC60 Service Manual (A5635A)
Controller Enclosure Troubleshooting 227
Troubleshooting
Errors During / After Firmware Download
Different patterns are displayed after downloading firmware. The patterns are shown in
Table 29.
Note
Note that a
!
!!
!
indicates the LED is On or Flashing.
.
Table 29
Firmware Download LEDs
Error LED Pattern
Download file is lacking header record. 0x61
Download file header fails checksum test. 0x64
Download file header contains unexpected download type. 0x65
The user should attempt to download a known good file. 0x67
Intermodule error call to flash function passed bad flash type. There is
a mismatch between the Boot Firmware and the Application Firmware.
The user must download matched versions of both controller
Bootware and controller Application Firmware.
0x91
Invalid address in flash device. 0x92
Unable to fully erase boot flash segments (bad voltage or device).
Replace the controller board.
0x95
Unable to fully erase file flash segments (bad voltage or device).
Replace the controller board.
0x96
Unable to program boot flash after 3 cycles of erase and write.
Replace the controller board.
0x97
Unable to program application file flash after 3 cycles of erase and
write. Replace the controller board.
0x98
Software load failure. There is a mismatch between the Boot Firmware
and the Application Firmware. The user must download matched
versions of both code types.
0xE6