HP SureStore E Disk Array FC60 Service Manual (A5635A)
Introduction 209
Troubleshooting
About Field Replaceable Units (FRUs)
The Disk Array FC60 consists of a Controller Enclosure and one or more SureStore E Disk
System SC10 enclosures. Table 24 identifies the disk array FRUs and whether they are
customer replaceable. See "Removal and Replacement" on page 287 for more information.
Table 24
Field Replaceable Units
Field Replaceable Units
Customer
Replaceable
Unit
Hot
Swappable
Modules
Disk Enclosure
Disk Modules Yes Yes
BCC (Bus Controller Card) Modules
– Note - disk enclosure should be powered down
when replacing the BCC.
No
Power Supply Modules Yes Yes
Disk Fan Modules Yes Yes
Disk Carrier Assembly No N/A
Power Button Assembly No N/A
Midplane/Mezzanine Assembly No N/A
Controller Enclosure
Controller Modules No Yes
Media Interphase Adapter (MIA) Yes Yes
Battery Backup Module Yes Yes
Controller Fan Module Yes Yes
SCSI Cables Yes No
Fibre Channel Cables Yes Yes
SIMM Memory (Controller Module) No No
Power Supply Modules Yes Yes
Power Supply Fan Module Yes Yes
Power Harnesses No N/A
Power Cage/Midplane Assembly No N/A
Controller Cage/Midplane Assembly No N/A
Misc. Hardware No N/A