HP SureStore E Disk Array FC60 Service Manual (A5277A)
'LVN$UUD\+LJK$YDLODELOLW\)HDWXUHV 71
Product Description
&RPSDUHVWKHUHODWLYHUHDGDQGZULWHSHUIRUPDQFHIRUDUUD\FRQILJXUDWLRQVZLWKWKH
SHUIRUPDQFHRIDVLQJOHVWDQGDORQHGLVNZKRVHSHUIRUPDQFHLV7KHUHDGDQGZULWH
SHUIRUPDQFHVKRZQLVWKHWKHRUHWLFDOPD[LPXPSHUIRUPDQFHUHODWLYHWRLQGLYLGXDOGLVN
SHUIRUPDQFH7KHSHUIRUPDQFHQXPEHUVDUHQRWEDVHGRQUHDGZULWHFDFKLQJ:LWKFDFKLQJ
WKHSHUIRUPDQFHQXPEHUVIRU5$,'ZULWHVLPSURYHVLJQLILFDQWO\
7DEOH 5$,'/HYHO&RPSDULVRQ6WRUDJH(IILFLHQF\&KDUDFWHULVWLFV
RAID Level Storage Efficiency
RAID 0 100%. All disk space is use for data storage.
RAID 1 and 0/1 50%. All data is duplicated, requiring twice the disk storage for a
given amount of data capacity.
RAID 3 and 5 One disk’s worth of capacity from each LUN is required to store
parity data. As the number of disks in the LUN increases, so does
the storage efficiency.
3-disk LUN: 66%
4-disk LUN: 75%
5-disk LUN: 80%
6-disk LUN: 83%
7DEOH 5$,'/HYHO&RPSDULVRQ5HODWLYH3HUIRUPDQFH&RPSDUHGWRDQ,QGLYLGXDO'LVN
LUN Configuration
Relative Read Performance
for Large Sequential Access
Relative Write Performance
for Large Sequential Access
RAID 0 The read and write performance of a RAID 0 LUN increases as
the multiple of the number of disks in the LUN. For example, a
4-disk RAID 0 LUN will achieve close to four times the
performance of a single disk.
RAID 1 mirrored pair Up to 2.0 > than single disk Equal to single disk
RAID 0/1 group with 10 disks Up to 10.0 > than single disk Up to 5.0 > than single disk
RAID 0/1 group with 6 disks Up to 6.0 > than single disk Up to 3.0 > than single disk
RAID 3 group with 5 disks Up to 4.0 > than single disk Up to 1.25 > than single disk
RAID-5 group with 5 disks Up to 4.0 > than single disk Up to 1.25 > than single disk