HP SureStore E Disk Array FC60 Service Manual (A5277A)
70'LVN$UUD\+LJK$YDLODELOLW\)HDWXUHV
5$,'/HYHO&RPSDULVRQV
7RKHOS\RXGHFLGHZKLFK5$,'OHYHOWRVHOHFWIRUD/81WKHIROORZLQJWDEOHVFRPSDUHWKH
FKDUDFWHULVWLFVIRUWKHVXSSRUWHG5$,'OHYHOV:KHUHDSSURSULDWHWKHUHODWLYHVWUHQJWKV
DQGZHDNQHVVRIHDFK5$,'OHYHODUHQRWHG
Note 5$,'LVVXSSRUWHGRQ:LQGRZV17DQG:LQGRZVRQO\
7DEOH
5$,'/HYHO&RPSDULVRQ'DWD5HGXQGDQF\&KDUDFWHULVWLFV
RAID Level Disk Striping Mirroring Parity
Handle multiple disk
failures?
RAID 0 Yes No No No. RAID 0 offers no data
redundancy or protection
against disk failure. RAID 0
should only be used for non-
critical data. The failure of a
single disk in a RAID 0 LUN
will result in the loss of all
data on the LUN.
RAID 1 No Yes No No
RAID 0/1 Yes Yes No Yes, providing both disks in
a mirrored pair do not fail.
RAID 3 Yes No Yes No
RAID 5 Yes No Yes No