HP SureStore E Disk Array FC60 Service Manual (A5277A)
664&RQWUROOHU(QFORVXUH0RGXOHV
2SHQWKHGLVNHQFORVXUHIURQWGRRU
3RZHUWKHGLVNHQFORVXUHGRZQE\VHWWLQJWKHSRZHUVZLWFKWRRII
CAUTION :KHQUHSODFLQJD6&6,FDEOHLWPXVWEHGLVFRQQHFWHGIURPERWKWKHFRQWUROOHU
HQFORVXUHDQGWKH%&&PRGXOH'LVFRQQHFWWKHFDEOHIURPWKHFRQWUROOHU
HQFORVXUHILUVWWKHQIURPWKHIDLOHG%&&'2127GLVNFRQQHFWWKH6&6,FDEOH
IURPWKH%&&ILUVWRUHUURUVPD\RFFXUZKHQWKHHQFORVXUHLVSRZHUHGRQ
5HPRYHWKH6&6,FDEOHIURPWKHFRQWUROOHUHQFORVXUHFRQQHFWRU
5HPRYHWKH6&6,FDEOHIURPWKH%&&
&RQQHFWWKH6&6,FDEOHWRWKH%&&FRQQHFWRU
&RQQHFWWKHRWKHUHQGRIWKH6&6,FDEOHWRWKHFRQWUROOHUHQFORVXUH6&6,FRQQHFWRU
'LVFRQQHFWDOOGLVNPRGXOHVIURPWKHEDFNSODQHFRQQHFWRUVE\UHOHDVLQJWKHORFNLQJ
OHYHUVDQGSXOOLQJPRGXOHRXWDERXWRQHLQFK7KLVVWHSLVUHTXLUHGWRHQVXUHWKHGLVN
PRGXOHVUHWXUQWRIXOORSHUDWLRQZKHQWKHHQFORVXUHLVSRZHUHGEDFNXS
3RZHUXSWKHGLVNHQFORVXUH
5HVHDWWKHGLVNPRGXOHVRQHDWDWLPH
D 3XVKWKHGLVNPRGXOHLQVORWLQWRVORWXQWLOLWVQDSVLQWRSODFH
E 2EVHUYHWKH'LVN)DXOW/('LWVKRXOGFRPHRQ:KHQWKH'LVN)DXOW/('JRHVRXW
LQVHUWWKHQH[WGLVNPRGXOH
F 5HSHDWWKHDERYHVWHSVXQWLODOOGLVNPRGXOHVDUHUHVHDWHG
2QFHWKHGLVNHQFORVXUHLVSRZHUHGXSFKHFNWKHVWDWXVRIWKHGLVNPRGXOHVXVLQJRQHRI
WKHVRIWZDUHPDQDJHPHQWWRROV,QLWLDOO\WKHGLVNPRGXOHVVWDWXVZLOOEHHLWKHU§ZULWH
IDLOHG¨RU§QRBUHVSRQVH¨(YHQWXDOO\DOOWKHGLVNPRGXOHVVKRXOGUHWXUQWR§UHSODFHG¨
VWDWXV2QFHWKLVRFFXUVWKHGLVNDUUD\ZLOOSHUIRUPDUHEXLOGDUHVXOWRI,2RFFXUULQJ
GXULQJWKHSHULRGWKHHQFORVXUHZDVSRZHUHGRII7KHGLVNDUUD\ZLOORSHUDWHDWUHGXFHG
SHUIRUPDQFHXQWLOWKHUHEXLOGLVFRPSOHWHG