HP SureStore E Disk Array FC60 Service Manual (A5277A)

&RQWUROOHU(QFORVXUH0RGXOHV 649
Removal and
Replacement
%DWWHU\%DFNXS8QLW%%85HPRYDO5HSODFHPHQW
ã+RW6ZDSSDEOH&RPSRQHQW
Note ,IWKH)DVW:ULWH&DFKH/('LVRQZKHQWKH%%8LVUHPRYHGIURPWKHHQFORVXUH
RULIWKH%%8IDLOVZULWHFDFKLQJZLOOEHGLVDEOHGDQGWKHZULWHFDFKHGDWDZLOO
EHZULWWHQWRGLVN+RZHYHULIDSRZHURXWDJHRFFXUVSULRUWRFRPSOHWLQJWKH
FDFKHZULWHWRGLVNGDWDPD\EHORVW7KHUHIRUHPDNHVXUHWKH)DVW:ULWH
&DFKH/('LVRIIEHIRUHUHSODFLQJWKH%%8
5HPRYLQJWKH%%8
 5HPRYHWKHFRQWUROOHUHQFORVXUHIURQWFRYHU6HH)URQW&RYHU5HPRYDO5HSODFHPHQW
RQSDJH 
 /RRVHQWKHIRXUVFUHZVWZRRQHDFKVLGHRQWKH%%86HH)LJXUH
CAUTION 7KH%%8ZHLJKVDSSUR[LPDWHO\SRXQGVVREHSUHSDUHGWRVXSSRUWLWV
ZHLJKWZKHQ\RXSXOOLWRXWRIWKHFKDVVLV7KH%%8LVQRWDVGHHSDVRWKHU
PRGXOHVDQGGLVHQJDJHVWKHHQFORVXUHVRRQHUWKDQ\RXPD\H[SHFW
 *UDVSWKHWZRKDQGOHVDQGVOLGHWKHPRGXOHRXWDERXWWZRLQFKHV
 *UDVSERWKVLGHVRIWKHPRGXOHZLWKERWKKDQGVDQGVOLGHLWRXWRIWKHHQFORVXUH