HP SureStore E Disk Array FC60 Service Manual (A5277A)
542&RQWUROOHU(QFORVXUH7URXEOHVKRRWLQJ
5HSODFLQJWKHGLVNDUUD\FRQWUROOHUPRGXOHLQFOXGLQJPHPRU\
5HSODFLQJWKHFRQWUROOHUHQFORVXUHPLGSODQHFRQWUROOHUFDUGFDJH
&RQWUROOHU6HUYLFLQJ1RWHV
+HUHDUHDIHZVXJJHVWLRQVWRFRQVLGHUZKHQVHUYLFLQJGLVNDUUD\FRQWUROOHUPRGXOHV
$OZD\VXVHSURSHUSUHFDXWLRQVDJDLQVWHOHFWURVWDWLFGLVFKDUJHZKHQUHPRYLQJDQG
KDQGOLQJGLVNDUUD\FRPSRQHQWV
$OZD\VUHDGSHUWLQHQWGRFXPHQWDWLRQ7KLVLQFOXGHVVRIWZDUHLQVWUXFWLRQVRQUHSODFLQJ
IDLOHGLQWHUIDFHFRPSRQHQWVDQGGRFXPHQWDWLRQVKLSSHGZLWKWKHUHSODFHPHQW)58V
SDUWLFXODUO\WKHNLWLQVWUXFWLRQV.LWLQVWUXFWLRQVRIWHQFRQWDLQWKHPRVWFXUUHQW
LQIRUPDWLRQUHJDUGLQJVHUYLFLQJ
$OZD\VVWRSDOO,2DFWLYLW\WRWKHFRQWUROOHUDQGDVVRFLDWHGGLVNPRGXOHVEHIRUH
UHSODFLQJWKHVXVSHFWRUIDLOHGFRPSRQHQWXQOHVVDOWHUQDWH/90OLQNVDUHSURSHUO\
FRQILJXUHG
0HPRU\PRGXOHVFRQWUROOHUPRGXOHVDQGWKHFRQWUROOHUHQFORVXUHFDUGFDJHDVVHPEO\
ZKLFKLQFOXGHVWKHPLGSODQHDUHQRWXVHUUHSODFHDEOH7KHVHFRPSRQHQWVPXVWEH
VHUYLFHGE\DTXDOLILHGWUDLQHGVHUYLFHWHFKQLFLDQRQO\
$IDLOHGFRQWUROOHUPRGXOHFDQEHKRWVZDSSHGLIWKHIDLOHGFRQWUROOHU,VRQHRID
UHGXQGDQWSDLU
,IFDFKHPLUURULQJLVHQDEOHGDQGRQHFRQWUROOHUPRGXOHIDLOVWKHUHPDLQLQJFRQWUROOHU
PRGXOHZLOODVVXPHRSHUDWLRQRIWKHGLVNDUUD\EXWZULWHFDFKHZLOOEHGLVDEOHG
5HPRYHWKHIURQWFRYHUWRVHUYLFHWKHFRQWUROOHUPRGXOHVRUWRYLHZWKH/('VRQHDFK
PRGXOH
0DNHVXUHWKDWWKHQHZFRQWUROOHUPRGXOHKDVWKHVDPHDPRXQWRIPHPRU\DVWKHRQH
\RXDUHUHSODFLQJ
Note 'RQRWVZDSDFRQWUROOHUZKHQWKHSRZHULVRII
6&6,LQWHUIDFHFDEOHVDUHQRWKRWVZDSSDEOH