HP SureStore E Disk Array FC60 Service Manual (A5277A)
482$5',$*2IIOLQH'LDJQRVWLF
Enable default cache mirroring SET
Default cache Block sizeReserved
Enable subsystem cache LED SET
0x2c 0x00 Drive negotiation Options. . . . . . . .
Negotiate for WIDE NOT SET
Negotiate for Synchronous Xfer Set for maximum rate
0x2d 0x00 Cache Battery Life Expiration Age. . . .0 days
0x2e 0x00 Cache battery expiration warning age .0 weeks
0x2f 0x22 Misc. options byte 3 . . . . . . . . . .
Enable Ultra Scsi Speeds between controllers NOT SET
Disable immediate avail. during LUN creation SET
Multi-parallel SCSI host RESET Prop. enable NOT SET
Default ECDE Value NOT SET
Alternate Cntrlr Reset Prop. Enable SET
0x30 0x00 Misc. options byte 4 . . . . . . . . . . 0x00
0x31 0x00 Background Disk Scrubbing Options. 0x00
0x32 0x00 Universal Transport Mechanism. . . . . Disabled
Bytes %.02x Reserved for future use . . . . . . . .
AR60DIAG> describe controller 0 channel 1
=============== JBOD connected to channel 1 ===============
Drive at address 0 . . . . . . OK
Drive at address 1 . . . . . . OK
Drive at address 2 . . . . . . OK
Drive at address 3 . . . . . . OK
Drive at address 4 . . . . . . OK
Fan #1. . . . . . . . . . . . . OK
Fan #2. . . . . . . . . . . . . OK
Supply #1 . . . . . . . . . . . ON AND OK
Supply #2 . . . . . . . . . . . ON AND OK
AR60DIAG> describe controller 0 channel 1 disk 2