HP-UX Diagnostic Tools
0x1b 0x00 Drive-side Queuing Options. . . . . . . .
Drv sorting OFF.
Dynamic queue depth
= optimized.
0x1c 0x04 Error reporting Option (Byte 0x1C) . . .
Report failed
drvs/dead LUNS at start of day
0x1d 0x80 Error reporting Option (Byte 0x1D) . . .
Rprt VU Unit Attn
as Chk Conditions
0x1e 0x00 UPS options. . . . . . . . . . . . . . . No
feature support
0x1f 0x00 AC Polling option. . . . . . . . . . . . Does
NOT POLL
0x20 0x00 UPS warning time options . . . . . . . . 0x00 0x.00
0x22 0x00 Low UPS BATTERY recharge time . . .0 minutes
0x24 0x00 Inquiry Non-owned LUN device type. . .0x.02x
0x25 0x00 Parity scan options. . . . . . . . . . .
Auto parity scan NOT
enabled.
0x26 0x00 LUN takeover UnitAtn ASC . . . . . . . . 0x00
0x27 0x00 Serial Status Display. . . . . . . . . . 0x00
0x28 0x04 Misc. options byte 0x28. . . . . . . . .
Synchronize NVSRAM is SET
Load Network Software is NOT SET
Report in Inquiry as SCSI-3 is NOT SET
Treat BusDeviceReset as BUS RESET is NOT SET
Disable use of FUA is NOT SET
Disable creation of default LUN NOT SET
0x29 0x2c Misc. options byte 0x29. . . . . . . . .
Don’t fail sub-encls drives on sub-enclsr failureSET
0x2a 0x64 Drive cmd timeout value. . . . . . . . . 10 seconds
0x2b 0x8a Caching Options. . . . . . . . . . . . .
Enable Write-Back cache SET
Enable cache WITHOUT batteries NOT SET