HP SureStore E Disk Array FC60 Service Manual (A5277A)
468$5',$*2IIOLQH'LDJQRVWLF
&RPPDQG'HVFULSWLRQV
7KLVVHFWLRQLQFOXGHVDFRPSOHWHGHVFULSWLRQRIHDFK$5',$*FRPPDQG7KHFRPPDQGV
DUHRUJDQL]HGDOSKDEHWLFDOO\DQGLQFOXGHXVDJHH[DPSOHV
%,1'
7KH%,1'FRPPDQGELQGVD/81WRWKHVSHFLILHGFRQWUROOHU,IDFRQWUROOHULVQRWVSHFLILHG
WKH/81ZLOOEHERXQGRQWKHGHIDXOWFRQWUROOHULGHQWLILHGE\WKHHQYLURQPHQWYDULDEOH
5$,'OHYHODQGWKHGLVNVLQFOXGHGLQWKH/81DUHLGHQWLILHGZKHQELQGLQJD/81
6\QRSVLV
bind controller # LUN #
([DPSOH
7KHIROORZLQJH[DPSOHELQGVD5$,'/81RQFRQWUROOHU7KH/81LVDVVLJQHGQXPEHU
DQGXVHVWZRGLVNVDQG
AR60DIAG> bind controller 1 lun 2
Enter Raid level (1:5)
Enter ’q’ to quit
1
Raid level 1 should have even number of drives
Enter the number of drives to be bound
Enter q to quit
2
Data for drive # 0
Enter channel number
1
Data for drive # 1
Enter disk number
0
Enter channel number
2
Enter disk number