HP SureStore E Disk Array FC60 Service Manual (A5277A)

0DMRU(YHQW/RJ(QWULHV 421
Managing the Disk Array
on HP-UX
5'$&4XLHVFHQFHDQG,&210DQDJHU(YHQWV
Event
Number Event Description Priority Category Component
0x4000 Shell SysWipe Controller: Logged
when a syswipe request is sent to the
controller. This routine is not called by
the controller SW or FW currently. If
logged it means the command was
entered through the shell interface. If
this entry is seen a corresponding
entry of
MEL_EV_ICON_SYS_WIPE_ALT
should also be logged by the alternate
controller.
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)
0x4001 NVSRAM Clear Sent to Alternate
Controller: Logged when an
NVSRAM clear message is sent to
the alternate controller. This is
normally logged as part of a mode
select command to the RDAC mode
page 0x2C. The companion entry of
MEL_EV_ICON_NV_CLR_ALT
should also be seen in the event log
along with this entry.
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)
0x4002 Shell SysWipe from Alternate
Controller: Logged when a syswipe
request is received by the alternate
controller. This is an unexpected log
entry that is logged when the routine
iconMgrSendSysWipe is executed
from the shell of the alternate
controller. This routine is not called by
the controller SW. The companion
entry of MEL_EV_ICON_SYS_WIPE
should also be logged if this entry is
seen.
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)