HP SureStore E Disk Array FC60 Service Manual (A5277A)
0DMRU(YHQW/RJ(QWULHV 419
Managing the Disk Array
on HP-UX
0x3010 Mode Select 0x3A--Global Hot
Spare Page: Logged when Mode
Select Page 0x3A (The global hot
spare page) is received.
Informational
(0x0)
Command
(0x3)
Controller
(0x8)
0x3012 Write Buffer Received: Logged
when Write Buffer is received to the
following buffer ids:
0xE8 - SubSystem Identifier
0xE9 - Subsystem Fault
0xEA - drive Fault
0xED - Host Interface Parameters
0xEE - user configuration options
0xF0 - BootP Storage
Informational
(0x0)
Command
(0x3)
Controller
(0x8)
0x3013 Controller Firmware Download
Started: Logged when controller
firmware download is started.
Informational
(0x0)
Command
(0x3)
Controller
(0x8)
0x3014 Disk Firmware Download: Logged
when drive firmware download has
started.
Informational
(0x0)
Command
(0x3)
Drive (0x1)
0x3019 Mode Select Active/Passive Mode:
Logged when a Mode Select
command to make the controller
Active is received.
Critical (0x1) Command
(0x3)
Controller
(0x8)
0x301A Disk Firmware Download Fail:
Logged when drive firmware
download has failed.
Informational
(0x0)
Command
(0x3)
Drive (0x1)
0x301B Disk Firmware Download
Complete: Logged when drive
firmware download has completed
successfully.
Informational
(0x0)
Command
(0x3)
Drive (0x1)
0x301C ESM Firmware Download Start:
Logged when ESM firmware
download has started.
Informational
(0x0)
Command
(0x3)
ESM (0x7)