HP SureStore E Disk Array FC60 Service Manual (A5277A)

0DMRU(YHQW/RJ(QWULHV 415
Managing the Disk Array
on HP-UX
0x2806 Disk Enclosure Device State
Change: Logged when SSM has
detected a change in an enclosure
device, other than a drive status.
Informational
(0x0)
Notification
(0x4)
ESM (0x7)
0x2808 Sub-Enclosure ID Not Unique:
Logged when the controller
determines that there are multiple
sub-enclosures with the same ID
value selected.
Informational
(0x0)
Notification
(0x4)
ESM (0x7)
0x2809 Subsystem Line Transitioned to
Good State: Logged when a
subsystem line has transitioned to the
Good state.
Informational
(0x0)
Notification
(0x4)
Unknown
(0x0)
0x280A Expected Subsystem Line Missing:
Logged when an expected subsystem
line is missing
Critical (0x1) Notification
(0x4)
Unknown
(0x0)
0x280B Subsystem Line Failed: Logged
when a subsystem line has
transitioned to the Failed state.
Critical (0x1) Notification
(0x4)
Unknown
(0x0)
0x280C Enclosure Transitioned to Good
State: Logged when an enclosure
has transitioned to the Good state.
Informational
(0x0)
Notification
(0x4)
ESM (0x7)
0x280D Disk Enclosure Component Failed:
Logged when an enclosure has
transitioned to the Failed state.
Critical (0x1) Notification
(0x4)
ESM (0x7)
0x280E Battery Low: Logged when the
battery is charge is low
Critical (0x1) Notification
(0x4)
Battery (0x9)
0x280F Redundant Path Not Available to
Devices: Logged when a redundant
path is not available to devices
Informational
(0x0)
Notification
(0x4)
ESM (0x7)
0x2810 Redundant Path to Devices
Restored: Logged when a redundant
path to devices is restored
Informational
(0x0)
Notification
(0x4)
ESM (0x7)