HP SureStore E Disk Array FC60 Service Manual (A5277A)

4140DMRU(YHQW/RJ(QWULHV
6XEV\VWHP0RQLWRU(YHQWV
0x2703 Recovered Processor DRAM Error:
Logged when the controller has
encountered recoverable processor
DRAM ECC errors (below the
maximum threshold)
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)
Event
Number Event Description Priority Category Component
0x2800 Power Supply State Changed:
Logged when a power supply
changes state
Informational
(0x0)
Notification
(0x4)
Power Supply
(0x2)
0x2801 UPS Battery Supplying Power to
Subsystem: The UPS battery is now
supplying power to the subsystem.
Informational
(0x0)
Notification
(0x4)
Battery (0x9)
0x2802 UPS Battery Good: The UPS battery
has charged and transitioned to the
good state
Informational
(0x0)
Notification
(0x4)
Battery (0x9)
0x2803 UPS Battery 2 Minute Warning: The
UPS battery has transitioned given
the 2 minute warning. The UPS has
signaled that it has 2 minutes of
power left before failing. The
controllers will flush any dirty data in
their caches and turn off data
caching.
Informational
(0x0)
Notification
(0x4)
Battery (0x9)
0x2805 Line State Change: Logged when a
discreet line state change is detected
and an AEN is posted. This can either
be a good to bad transition or bad to
good. This does not include the cache
battery line. Cache battery events are
logged by the cache manager
Informational
(0x0)
Notification
(0x4)
Unknown