HP SureStore E Disk Array FC60 Service Manual (A5277A)
0DMRU(YHQW/RJ(QWULHV 413
Managing the Disk Array
on HP-UX
6WDUWRI'D\(YHQWV
Event
Number Event Description Priority Category Component
0x2600 ACS Download Start: Logged when
an ACS Download is started
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)
0x2601 ACS Download Completed: Logged
after the controller has been rebooted
after auto code synchronization has
been preformed. An ASC/ASCQ
value of 0x29/0x82 is also logged with
this event
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)
0x2602 ACS Failed: Logged when auto code
synchronization failed
Informational
(0x0)
Error (0x1) Controller
(0x8)
0x2603 Default LUN Created at SOD:
Logged when the default LUN was
created at SOD
Informational
(0x0)
State (0x5) Volume (0xD)
0x2604 Persistent Memory Parity Error:
Logged when SOD detects that the
persistent memory parity error state
has been set.
Informational
(0x0)
Error (0x1) Controller
(0x8)
0x2605 Start of Day Complete: Logged
when the controller has completed
initialization.
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)
0x2700 RPA Memory Parity Error: Logged
during start of day if a parity error is
found in RPA memory.
Informational
(0x0)
Error (0x1) Controller
(0x8)
0x2702 RPA Unexpected Interrupt: Logged
when an unexpected RPA Interrupt is
detected
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)