HP SureStore E Disk Array FC60 Service Manual (A5277A)

0DMRU(YHQW/RJ(QWULHV 409
Managing the Disk Array
on HP-UX
0x2247 Unrecovered Interrupted Write:
Logged when a LUN is marked DEAD
due to a media error failure during
SOD. An error occurred during
Interrupted Write processing causing
the LUN to transition to the DEAD
State. SK/ASC/ASCQ =
0x06/0x3F/0xEB will be offloaded for
this error.
Critical (0x1) Notification
(0x4)
Volume (0xD)
0x2248 Unrecovered Write Failure: Logged
when the configuration manager
posts and UA/AEN of ASC/ASCQ =
0x3F/0x80 indicating the controller set
the drive state to “Failed – Write
Failure”.
Critical
(0x1)
Failure
(0x2)
Drive (0x1)
0x2249 Disk Too Small: Logged when the
configuration manager posts and
UA/AEN of ASC/ASCQ = 0x3F/0x8B
indicating the controller set the drive
state to “Drive Capacity < Minimum”.
Critical
(0x1)
Notification
(0x4)
Drive (0x1)
0x224A Wrong Sector Size: Logged when
the configuration manager posts and
UA/AEN of ASC/ASCQ = 0x3F/0x8C
indicating the controller set the drive
state to “Drive has wrong blocksize”.
Critical
(0x1)
Notification
(0x4)
Drive (0x1)
0x224B Disk Format Failed: Logged when
the configuration manager posts and
UA/AEN of ASC/ASCQ = 0x3F/0x86
indicating the controller set the drive
state to “Failed – Format failure”.
Critical
(0x1)
Notification
(0x4)
Drive (0x1)
0x224C Wrong Disk Removed / Replaced:
Logged when the configuration
manager posts and UA/AEN of
ASC/ASCQ = 0x3F/0x89 indicating
the controller set the drive state to
“Wrong drive removed/replaced”.
Informational
(0x0)
Notification
(0x4)
Drive (0x1)