HP SureStore E Disk Array FC60 Service Manual (A5277A)

4060DMRU(YHQW/RJ(QWULHV
0x2230 Configuration Manager Call to Fail
Disk: Logged when the configuration
manager state machine has been
called to fail the device. This is an
additional event that indicates the
configuration manager has
determined that processing has to be
done in order to fail the device.
Appearance of this entry depends on
the drives state previous state prior to
being failed.
Informational
(0x0)
Notification
(0x4)
Drive (0x1)
0x2231 Configuration Manager Mark Disk
Removed: Logged when the
configuration manager state machine
is going to mark a drive removed.
Informational
(0x0)
Notification
(0x4)
Drive (0x1)
0x2232 Disk Already Removed: Logged
when the configuration manager is
called to remove a drive that has
already been removed.
Informational
(0x0)
Notification
(0x4)
Drive (0x1)
0x2233 Unassigned Disk Marked as
Removed: Logged when an
unassigned drive has been marked as
removed by the configuration
manager.
Informational
(0x0)
Notification
(0x4)
Drive (0x1)
0x2234 Disk Removed Before Rebuild
Completed: Logged when a drive
has been removed that hasn’t finished
reconstruction, usually happens when
a drive that is waiting for
reconstruction to begin is removed.
Informational
(0x0)
Notification
(0x4)
Drive (0x1)
0x2235 Optimal or Replaced Disk
Removed: Logged when an optimal
or replaced drive has been removed
Informational
(0x0)
Notification
(0x4)
Drive (0x1)