0x2229 Failed Disk Internally: Logged when
the configuration manager internally
fails the device.
Informational
(0x0)
Notification
(0x4)
Drive (0x1)
0x222A Unassigned Disk Specified as
GHS: Logged when an unassigned
drive is specified as a global hot spare
Informational
(0x0)
Notification
(0x4)
Drive (0x1)
0x222B Disk Cold Replaced: Logged when
the configuration manager finds a
drive that has been cold replaced. i.e.
Replace when the controller &
subsystem were powered off.
Informational
(0x0)
Notification
(0x4)
Unknown
(0x0)
0x222C Disk Unassigned: Logged when a
drive is to be marked unassigned,
also Logged if an unknown drive that
was part of a LUN is to be brought
online
Informational
(0x0)
Notification
(0x4)
Drive (0x1)
0x222D Fail Disk Function Called: Logged
when external interface or
cfgDriveFailed is called.
Informational
(0x0)
Notification
(0x4)
Drive (0x1)
0x222E Mark Disk Removed: Logged when
a drive has is to be marked removed.
Informational
(0x0)
Notification
(0x4)
Drive (0x1)
0x222F Mark Disk for Replace and Rebuild:
Logged when a notification is
received that a failed drive is to be
replaced and that data reconstruction
on this device should begin.
Informational
(0x0)
Notification
(0x4)