HP SureStore E Disk Array FC60 Service Manual (A5277A)

0DMRU(YHQW/RJ(QWULHV 403
Managing the Disk Array
on HP-UX
0x2214 One or More Sundry Disks Created:
Logged when configuration manager
creates 1 or more sundry drives.
Informational
(0x0)
Notification
(0x4)
Unknown
(0x0)
0x2215 UA/AEN Posted for Failed Disk:
Logged when configuration manager
posts a UA/AEN for a failed drive.
Informational
(0x0)
Notification
(0x4)
Unknown
(0x0)
0x2216 LUN Piece Out of Service (OOS):
Logged when the configuration
manager take a piece of the specified
LUN out of service
Informational
(0x0)
Notification
(0x4)
Drive (0x1)
0x2217 LUN Piece Fail: Logged when a
piece of specified LUN is failed.
Informational
(0x0)
Notification
(0x4)
Drive (0x1)
0x2218 LUN Piece Fail During
Uncompleted Write: Logged when a
piece of specified LUN is failed during
uncompleted write processing
Informational
(0x0)
Notification
(0x4)
Drive (0x1)
0x2219 LUN Piece Removed: Logged when
a piece of specified LUN has been
removed
Informational
(0x0)
Notification
(0x4)
Drive (0x1)
0x221A LUN Piece Replace: Logged when a
piece of specified LUN has been
replaced
Informational
(0x0)
Notification
(0x4)
Drive (0x1)
0x221B LUN Piece In Service: Logged when
the configuration manager places a
LUN piece in service.
Informational
(0x0)
Notification
(0x4)
Drive (0x1)
0x221C Disk Group Offline: Logged when an
entire drive group is placed online the
first 16 devices of the drive group are
recorded in the data buffer.
Informational
(0x0)
Notification
(0x4)
Volume
Group (0xE)
0x221D Disk Group Online: Logged when an
entire drive group is placed online.
Informational
(0x0)
Notification
(0x4)
Volume
Group (0xE)
0x221E LUN Initialized: Logged when a LUN
has been created.
Informational
(0x0)
Notification
(0x4)
Volume (0xD)