HP SureStore E Disk Array FC60 Service Manual (A5277A)
4000DMRU(YHQW/RJ(QWULHV
0x2117 Controller Cache Manager Error
Cleared: On occasion CCM may log
an error prematurely and then clear it
later. For example errors may be
logged when the alternate controller
is removed from the subsystem. If the
controller is replaced before a write is
done CCM will cancel the errors
logged since the controller is replaced
and functioning normally.
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)
0x2118 Memory Parity ECC Error: Logged a
memory parity error occurs and
information on the error is available
Informational
(0x0)
Error (0x1) Controller
(0x8)
0x2119 Recovered Data Buffer Memory
Error: Logged when the controller
has detected and corrected a
recoverable error in the data buffer
memory.
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)
0x211A Cache Error Was Corrected:
Logged when the cache manager has
corrected using the alternate
controllers cache memory
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)