HP SureStore E Disk Array FC60 Service Manual (A5277A)

3940DMRU(YHQW/RJ(QWULHV
9''(YHQWV)
Event
Number Event Description Priority Category Component
0x2001 Repair LUN Begin: Logged when a
repair operation is started for the
specified unit.
Informational
(0x0)
Notification
(0x4)
Volume (0xD)
0x2005 LUN Internally Failed: Logged when
the specified LUN is internally failed.
Informational
(0x0)
Failure
(0x2)
Volume (0xD)
0x200A Data Parity Mismatch: Logged when
a data/parity mismatch is detected
during data scrubbing
Informational
(0x0)
Error (0x1) Volume (0xD)
0x200F Begin Synchronize Cache: Logged
when cache synchronization is begun
from an external (to VDD) source
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)
0x2010 End Synchronize Cache: Logged
when cache synchronization for the
specified unit completes
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)
0x2011 Flush Cache Begin: Logged when
an operation to flush cache for the
specified unit is begun
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)
0x2012 Flush Cache End: Logged when an
operation to flush cache for the
specified unit has completed.
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)
0x2013 Cache Recovered at SOD or at
Change Owner: Logged when
unwritten data and parity is recovered
from cache at start-of-day or during a
forced change in LUN ownership
between the controllers.
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)
0x2014 VDD Error: Logged when VDD logs
an error.
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)