HP SureStore E Disk Array FC60 Service Manual (A5277A)

0DMRU(YHQW/RJ(QWULHV 391
Managing the Disk Array
on HP-UX
6&6,6RXUFH'ULYHU(YHQWV
Event
Number Event Description Priority Category Component
0x1101 SCSI Chip Exception Condition:
Logged when the SRC driver detects
an exception condition from the SCSI
chip
Informational
(0x0)
Error (0x1) Controller
(0x8)
0x1102 Host SCSI Bus Reset: Logged when
the source SCSI driver asserts the
RESET signal on the host SCSI bus.
This is usually done as a response to
have a host bus reset propagated to it
by the alternate controller in a cluster
environment.
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)
0x1103 Host SCSI Bus Reset Received:
Logged when a host bus reset was
received and the controller is going to
propagate it to the alternate controller
in a wolf pack environment. Log
entries for Host Bus Reset Received
and Host Bus Reset should always
appear in pairs in the system log.
Informational
(0x0)
Notification
(0x4)
Controller
(0x8)
0x1104 Unknown Interrupt: Logged when
the source SCSI driver detects an
unknown interrupt
Informational
(0x0)
Error (0x1) Controller
(0x8)