HP SureStore E Disk Array FC60 Service Manual (A5277A)

3900DMRU(YHQW/RJ(QWULHV
0x1010 Disk SMART Event: The logged
device generated a PFA condition
Informational
(0x0)
Error (0x1) Drive (0x1)
0x1012 Destination Driver Unrecovered
Error: Logged when the destination
driver has an unrecovered error from
the drive.
Informational
(0x0)
Error (0x1) Controller
(0x8)
0x1013 Destination Diagnostic Failure:
Logged when destination driver level 0
diagnostics failed for the specified
channel
Informational
(0x0)
Error (0x1) Controller
(0x8)
0x1014 Reassign Block Due to Write
Failure: Logged when the destination
driver issues a reassign block to the
drive due to a write failure.
Informational
(0x0)
Error (0x1) Controller
(0x8)
0x1015 Bad Mode Select Parameters:
Logged when the controller has
detected a drive with Mode Select
parameters that are not recommended
or which could not be changed.
Informational
(0x0)
Error (0x1) Controller
(0x8)