HP SureStore E Disk Array FC60 Service Manual (A5277A)
0DMRU(YHQW/RJ(QWULHV 389
Managing the Disk Array
on HP-UX
Major Event Log Entries
2QILUPZDUHYHUVLRQ+3DQGODWHUPDMRUHYHQWORJJLQJLVXVHGWRUHFRUGGLVNDUUD\
HYHQWVDQGDFWLYLW\7KHIROORZLQJWDEOHGHVFULEHVWKHHYHQWVWKDWPD\EHORJJHG
'HVWLQDWLRQ'ULYHU(YHQWV
Event
Number Event Description Priority Category Component
0x1001 Channel Failure: Logged when the
parallel SCSI destination driver detects
a channel failure
Informational
(0x0)
Failure
(0x2)
Chip (0XC)
0x1007 Memory Allocation Failed: Logged
when memory allocation failed
Informational
(0x0)
Error (0x1) Controller
(0x8)
0x1009 Memory Parity Error: Logged when a
memory parity error is detected by the
destination driver
Informational
(0x0)
Error (0x1) Controller
(0x8)
0x100A Disk Check Condition: The driver
was unable to recover the specified
device. Returned a check condition to
the driver and driver retries have been
exhausted
Informational
(0x0)
Error (0x1) Drive (0x1)
0x100B Destination SOD Error: Logged when
the destination driver can’t complete
SOD initialization successfully
Informational
(0x0)
Error (0x1) Controller
(0x8)
0x100E Unexpected Interrupt: Logged due to
an unexpected interrupt with no active
device on chip
Informational
(0x0)
Error (0x1) Controller
(0x8)
0x100F Bus Parity Error: Logged when a Bus
Parity error is detected by the
destination driver
Informational
(0x0)
Error (0x1) Controller
(0x8)