HP SureStore E Disk Array FC60 Service Manual (A5277A)

6WDWXV&RQGLWLRQVDQG6HQVH&RGH,QIRUPDWLRQ 371
Managing the Disk Array
on HP-UX
6&6,6HQVH&RGHV
7DEOHOLVWVWKH6&6,VHQVHFRGHVWKDWPD\EHUHWXUQHGDVSDUWRIWKHORJHQWU\7KLV
LQIRUPDWLRQPD\EHKHOSIXOLQWHUSUHWLQJORJHQWULHV2QO\WKH$GGLWLRQDO6HQVH&RGHDQG
$GGLWLRQDO6HQVH&RGH4XDOLILHUILHOGVDUHUHTXLUHGWRLGHQWLI\HDFKFRQGLWLRQ
7DEOH
6&6,6HQVH&RGHV
Additional
Sense
Code
Additional
Sense Code
Qualifier Interpretation
00 00 No Additional Sense Information
The controller has no sense data available for the requesting
host and addressed logical unit combination.
04 01 Logical Unit is in the Process of Becoming Ready
The controller is executing its initialization functions on the
addressed logical unit. This includes drive spinup and validation
of the drive/ logical unit configuration information.
04 02 Logical Unit Not Ready, Initializing Command Required
The controller is configured to wait for a Start Stop Unit com-
mand before spinning up the drives, but the command has not
yet been received.
04 04 Logical Unit Not Ready, Format In Progress
The controller previously received a Format Unit command
from an initiator, and is in the process of executing that com-
mand.
04 81 Storage Module Firmware Incompatible - Manual Code Syn-
chronization Required
04 A1 Quiescence Is In Progress or Has Been Achieved