HP SureStore E Disk Array FC60 Service Manual (A5277A)
0DQDJLQJWKH'LVN$UUD\8VLQJ$UUD\0DQDJHU 331
Managing the Disk Array
on HP-UX
5HIRUPDWWLQJWKH'LVN$UUD\0HGLD
,IQHFHVVDU\WKHGLVNDUUD\PHGLDFDQEHUHIRUPDWWHG7KLVSURFHVVFOHDUVWKHGLVNDUUD\
FRQILJXUDWLRQLQIRUPDWLRQVWRUHGRQHDFKGLVN7KLVXQELQGVDOOWKH/81VRQWKHGLVNDUUD\
GHVWUR\LQJDOOGDWDLQWKHSURFHVV7KHRQO\/81WKDWZLOOUHPDLQIROORZLQJWKLVSURFHGXUH
LVWKHGHIDXOW/81D0E\WH5$,'/81
CAUTION 7KLVSURFHVVGHVWUR\VDOOGDWDRQWKHGLVNDUUD\DQGUHPRYHVDQ\/81
VWUXFWXUHWKDWKDVEHHQFUHDWHG,IWKHUHLVGDWDRQWKHGLVNDUUD\PDNHVXUH
LWLVEDFNHGXSEHIRUHSHUIRUPLQJWKLVVWHS
7RUHIRUPDWWKHGLVNDUUD\PHGLDW\SH
DPXWLOV\VZLSH>IRUFH@$UUD\,'!
IRUFHUHIRUPDWVWKHGLVNDUUD\HYHQLIWKHUHDUH/81VRQLW,IWKLVSDUDPHWHULVQRW
LQFOXGHGWKHFRPPDQGZLOOH[HFXWHRQO\LIWKHUHDUHQR/81VRQWKHGLVNDUUD\RWKHU
WKDQ/81
Note $VWKHV\VZLSHRSHUDWLRQH[HFXWHVZDWFKWKHDFWLYLW\/('VRQWKHGLVN
PRGXOHV(DFK/('VKRXOGLOOXPLQDWHEULHIO\VWDUWLQJZLWKWKHILUVWGLVNRQWKH
ILUVWFKDQQHODQGFRQWLQXLQJLQDRUGHUO\VHTXHQFHWKURXJKDOOWKHGLVNV,IWKH
/('RQDQ\GLVNUHPDLQVRQQRWLFHDEO\ORQJHUWKDQWKHRWKHUVLWPD\LQGLFDWH
WKDWWKHV\VZLSHRSHUDWLRQKDVHQFRXQWHUHGDSUREOHP,QWKLVFDVHUHWU\WKH
V\VZLSHRSHUDWLRQ'RQRWFRQWLQXHZLWKWKHQH[WVWHSXQWLOWKHV\VZLSHKDV
FRPSOHWHGVXFFHVVIXOO\
:DLWILYHPLQXWHVDIWHULVVXLQJWKHV\VZLSHEHIRUHVHQGLQJDQRWKHUFRPPDQGWR
WKHDUUD\6HQGLQJDFRPPDQGWRRTXLFNO\PD\UHVXOWLQD'HYLFH1RW5HDG\
HUURU