HP SureStore E Disk Array FC60 Service Manual (A5277A)

274$GGLQJ&DSDFLW\WRWKH'LVN$UUD\
7DEOH %HKDYLRU:KHQ0RYLQJ'LVN0RGXOHV+RWZLWK+3)LUPZDUH
Moving this
type of disk….
to a slot previously occupied
by this type of disk…. results in this behavior.
LUN None or Unassigned Disk remains part of its original LUN. If disk was
moved from another array, the receiving array will try
to create a new LUN to accommodate the disk.
Global Hot Spare If the disk is resident, it remains part of its original
LUN.
If the disk is foreign (from another array), the disk
becomes a global hot spare.
Failed LUN Disk Disk replaces failed disk and becomes part of new
LUN. All original LUN data on disk is lost.
Optimal LUN Disk (original disk
moved to another slot in the array)
Disk remains part of its original LUN. If the disk was
moved from another array, the receiving array will try
to create a new LUN to accommodate the disk.
Global hot spare None or Unassigned Disk remains global hot spare
Global Hot Spare Disk remains global hot spare
Failed LUN Disk Disk replaces failed disk and becomes part of LUN
Optimal LUN Disk (original disk
moved to another slot in the array)
Disk remains global hot spare
Unassigned or
new
None or Unassigned Disk remains unassigned
Global Hot Spare Disk becomes a global hot spare.
Failed LUN Disk Disk replaces failed disk and becomes part of LUN
Optimal LUN Disk (original disk
moved to another slot in the array)
Disk remains unassigned