HP SureStore E Disk Array FC60 Service Manual (A5277A)
272$GGLQJ&DSDFLW\WRWKH'LVN$UUD\
7DEOH %HKDYLRU:KHQ0RYLQJ'LVN0RGXOHV+RWZLWK+3)LUPZDUHDQGODWHU
Moving this type
of disk….
to a slot previously
occupied by this type of
disk….
results in this behavior.
LUN None or Unassigned Disk becomes unassigned. All data on disk is lost.
Global Hot Spare Disk becomes a global hot spare. All data on disk is
lost.
Failed LUN Disk Disk replaces failed disk and becomes part of new
LUN. All original LUN data on disk is lost.
Optimal LUN Disk (original
disk moved to another slot in
the array)
Disk becomes part of LUN. All original LUN data on
disk is lost.
Global hot spare None or Unassigned Disk remains global hot spare
Global Hot Spare Disk remains global hot spare
Failed LUN Disk Disk replaces failed disk and becomes part of LUN
Optimal LUN Disk (original
disk moved to another slot in
the array
Disk becomes part of LUN.
Unassigned or new None or Unassigned Disk remains unassigned.
Global Hot Spare Disk becomes a global hot spare.
Failed LUN Disk Disk replaces failed disk and becomes part of LUN.
Optimal LUN Disk (original
disk moved to another slot in
the array)
Disk becomes part of LUN.